BELGISCHE MARITIEME LIGA  vzw.
LIGUE MARITIME BELGE  asbl.

Koninklijke Vereniging - Société Royale

DOSSIER

 

Hull biofouling environmentally worse than ballasting


The entry into force of the Ballast Water Management Convention (BWMC) this September will not prevent the transfer of invasive aquatic species (IAS) unless there is mandatory legislation in place to prevent biofouling on ships’ hulls.

At a presentation delivered at the World Ocean Council’s Sustainable Ocean Summit last December, IMO’s Marine Environmental Division’s technical office Dr Theofanis Karyannis revealed that hull biofouling could be more damaging than ballast water transfer.

Endorsing this view, Subsea Industries’ chairman, Boud Van Rompay, said: “The transfer of IAS in ballast water has been addressed with the ratification of the BWM Convention, but currently there is no legislation to prevent the transfer of IAS on ships’ hulls though fouling, only guidelines.”

While there is ongoing evaluation of the Biofouling Guidelines set out in MEPC.1/ Circ.811, there has been little support from IMO member states for a new mandatory instrument to reduce the impact of bioufouling. Aside from the guidelines, the issue of biofouling is thought not to be on the agenda of the MEPC or any other IMO committee.

There has been a number of studies comparing the transfer of IAS through ballast with that transferred by hull fouling. Some have concluded that hull fouling is more environmentally damaging than IAS relocated through ballasting operations.

In his paper ‘Building Partnerships to Address the Global Impacts from Aquatic Biofouling’, Dr Karyannis revealed a number of areas where hull biofouling was the primary factor for IAS.

In New Zealand, for example, biofouling was found to be responsible for 69% of IAS, as opposed to just 3% from ballast water. In Port Phillip Bay, Australia, 78% of IAS reported was from ships’ hulls with 20% from ballast water. In the North Sea the figure was 57% over 38% and in US waters, hull biofouling accounted for 36% of IAS, compared to 20% from ballast water.

“The IAS threat is increasing especially since antifouling systems in use since the ban on tributyltin (TBT) are less effective in eliminating hull fouling,” said Van Rompay. “Some species have developed a resistance to copper biocides and are thriving in ports and harbours where copper and organotin residues are high.”


Hull  cleaning  key

According to Van Rompay, frequent in-water hull cleaning of a hard, inert coating is the key to preventing IAS translocation, since the removal of micro- and macro-fouling acquired locally poses no risk whatsoever.

However, there is a dichotomy in that the in-water cleaning of biocidal antifouling systems is banned in many ports and harbours around the world, as the chemicals in these coatings pose an environmental hazard of their own. Cleaning macro-fouling from these hulls also damages the coatings.

“The only real answer to preventing the spread of IAS is by ensuring that ships sail with a clean hull from their point of origin. Only a non-toxic hard-type coating and regular in-water cleaning can achieve this. Indeed, many ports and harbours permit the in-water cleaning of this type of coating system. Effective biofouling control is also the most efficient way of reducing fuel consumption and greenhouse gas emissions,” Van Rompay concluded.

 

 

  LMB-BML 2007 Webmaster & designer: Cmdt. André Jehaes - email andre.jehaes@lmb-bml.be
 Deze site werd geoptimaliseerd voor een resolutie van 1024 x 768 en IE -11-Edge
Ce site a été optimalisé pour une résolution d'écran de 1024 x 768 et IE -11- Edge